A UPS is the equipment that keeps critical systems running when the grid fails — data centers, telecom rooms, hospitals and industrial plants all rely on it. Inside, power is converted twice: the rectifier turns AC to DC and the inverter turns it back, while the battery charger and control electronics work continuously. All of that conversion generates heat, and a UPS that runs hot is a UPS that fails early. Cooling is not a detail; it is a reliability requirement.
This guide covers what generates heat inside a UPS, the heat sink and cold plate structures that fit each stage, and the questions to ask a manufacturer before you commit. For the general principle behind power electronics cooling, see our power electronics cooling application page.
Why UPS Cooling Is a Reliability Requirement
- Continuous double conversion — an online UPS converts AC→DC→AC at all times, so the power modules are under load continuously, not in bursts.
- Compact, sealed cabinets — UPS hardware is packed into enclosures that limit airflow and leave little thermal margin.
- 24/7 duty with long life expectations — a UPS is expected to run for years; heat is the leading factor that degrades capacitors and power devices.
- Failure cost is high — a UPS failure can take down the very loads it protects, so the cooling path is sized for sustained reliability.
What Generates Heat Inside a UPS
- Rectifier modules (AC→DC) — convert the grid input; high switching losses.
- Inverter modules (DC→AC) — the output stage that powers the load; highest-flux source.
- Battery charger and DC-DC stages — charge and condition the battery bank.
- IGBT and SiC power modules — the switching devices in the rectifier and inverter; junction temperature directly affects efficiency and lifetime.
The IGBT / SiC power module is the highest-flux source in a UPS, so that is where the heat sink choice makes or breaks the design. For how IGBT cooling is approached in related power conversion, see our solar inverter & IGBT heat sink guide and EV charger heat sink guide.
UPS Heat Sink Structures
Skived fin heat sinks for medium-power modules
For the rectifier, charger and lower-power conversion modules, skived fins deliver high fin density in a one-piece structure with no interface between fin and base. On BY Thermal's in-house platforms, skived fins reach a minimum fin thickness of 0.05 mm on aluminum and copper, with fin heights up to 150 mm in aluminum and 60 mm in copper. For the full capability, see our guide to skived heat sinks.
Extruded + CNC heat sinks for cost-sensitive stages
Where the profile is stable and volume is high, an extruded aluminum sink with CNC-machined mounting faces is the economical baseline. Because tooling is involved for extrusion, this route suits designs that will not change — see custom extruded aluminum heat sinks.
Liquid cold plates for high-power UPS stages
For large UPS units — data center and industrial UPS — the inverter and rectifier modules can run on a liquid cold plate. BY Thermal manufactures cold plates in vacuum-brazed and friction-stir-welded constructions — see vacuum-brazed liquid cold plates and FSW cold plates — with CNC-machined mounting faces for the power modules.
Complete thermal assemblies
UPS builders often receive the heat sink, fan or cold plate, mounting frame and surface finish as one delivered unit. See our custom thermal assemblies page for how the processes combine under one roof.
Key Specs for UPS Heat Sinks
- Material — aluminum for cost and weight in air-cooled stages; copper where the highest thermal conductivity is needed under the module. Copper also allows skived copper fins up to 60 mm where needed.
- Module mounting flatness — the power module's base sits on the heat sink; flatness is a contact-interface spec you should ask to see verified on production parts.
- CNC precision — mounting datums and hole positions held to better than 0.02 mm repeat positioning on BY Thermal's platforms.
- Size capability — large rectifier and inverter sinks need a capable platform: BY Thermal handles 3500 mm maximum skiving length and 1200 mm maximum fin width.
- Thermal simulation before tooling — BY Thermal runs thermal simulation and thermal analysis on the design and provides DFM feedback on manufacturability and cost before you cut metal.
What to Ask a UPS Heat Sink Manufacturer
The reference guide 10 Questions to Ask When Choosing a Skived Fin Heat Sink Manufacturer covers the general checklist. For UPS work, add these five:
- Do you control the processes in-house? At BY Thermal, the skiving machines used for customer production are designed and built by our sister factory, Dongguan Weihang Industrial Co., Ltd., and operated by our own team at Dongguan Baoyue Technology Co., Ltd. Same owner, one group — capacity, scheduling and quality stay under one roof.
- What module mounting flatness do you guarantee, and how do you verify it? Ask for the CMM / gauge result, not a nominal.
- Can you build both air-cooled and liquid-cooled structures, in both aluminum and copper? BY Thermal routinely produces skived fins, CNC bases and liquid cold plates in both materials in-house.
- Do you run thermal simulation before cutting metal? Thermal simulation and DFM feedback on the design are part of the process, with free thermal design support after order placement.
- How fast is a prototype? Prototypes ship in 15–25 days, running on the same in-house machines and parameters as production.
Prototype, MOQ and Quality
- Prototype lead time: 15–25 days, running on the same in-house machines and parameters as production — the sample represents what you receive at volume.
- MOQ: BY Thermal generally does not set an MOQ. Validate a single prototype first, then scale.
- Quality system: ISO 9001, with inspection built into the production flow and a quality guarantee (typically one year, excluding man-made damage).
How BY Thermal Approaches UPS Cooling
BY Thermal is a custom thermal solutions manufacturer — we do not sell catalog heat sinks. Every air-cooled sink, liquid cold plate and thermal assembly is engineered and manufactured to your drawing, thermal budget and volume.
BY Thermal manufactures custom heat sinks and liquid cold plates for power electronics, laser equipment, AI servers, photovoltaic inverters and telecom. For UPS and power conversion work, we combine:
- Skived fin capability with the 0.05 mm minimum fin and up to 3500 mm maximum skiving length on our largest platform;
- CNC machining of module mounting faces and features with 0.02 mm repeat positioning;
- Liquid cold plates in vacuum-brazed, FSW and tube-type constructions — see custom liquid cold plate manufacturing;
- Surface treatment applied to your corrosion and reliability requirements. See surface treatment.
If you are cooling a UPS, power module or any power conversion system — send us your drawing and thermal budget. Our application engineers will run a first thermal review and DFM check before you cut metal — get a quote.
Frequently Asked Questions
What heat sink is used in a UPS?
Medium-power rectifier, charger and control modules use skived or extruded fin heat sinks; high-power inverter and IGBT stages use liquid cold plates. The choice depends on power rating, available cooling loop and cabinet layout.
Why does IGBT temperature matter in a UPS?
Junction temperature directly affects switching efficiency and module lifetime. A poorly cooled power module runs hot, loses efficiency and fails early — which is why the cooling path is engineered for continuous double-conversion duty.
Can you make copper heat sinks for UPS power modules?
Yes. BY Thermal skives copper fins up to 60 mm height and CNC-machines copper mounting bases in routine production.
Do you provide thermal simulation for UPS heat sinks?
Yes. Thermal simulation and thermal analysis are run on the design, with free thermal design support after order placement.