Custom Heat Sink & Cold Plate Manufacturing:
Built to your drawings. Optimized for manufacturability. Manufactured for reliable performance.

LIQUID COOLING

Direct Liquid Cooling

Indirect Liquid Cooling

Indirect Liquid Cooling

Home / Archive by category "LIQUID COOLING"

Introduction

While direct liquid cooling (in which coolant contacts hot surfaces directly) often gets the spotlight for maximum performance, many practical systems favor indirect liquid cooling due to its balance of safety, reliability, and flexibility. In this article, we dive into what indirect liquid cooling is, its principles, advantages and trade-offs, design best practices, and applications — particularly in battery systems, power electronics, and data centers.

What Is Indirect Liquid Cooling?

 

In indirect liquid cooling, a solid thermal interface (such as a cold plate, liquid jacket, or embedded channels) isolates the coolant from the heat-generating component. Heat flows from the source → interface medium → coolant. Because there is no direct contact, risks such as electrical shorting or contamination are mitigated, making the approach safer and more practical in many applications.

Typical configurations include:

Cold plate cooling with a metal plate between device and coolant

Liquid jackets / conduits mounted externally

Embedded channels / manifolds within a housing

Heat spreaders + coolant circuit coupling

This strategy is widely adopted in battery thermal management systems (BTMS) for EVs and hybrid systems.

 

Why Choose Indirect Liquid Cooling? — Advantages & Trade-offs

 

Advantages

 

Electrical Isolation & Safety
Because the coolant does not contact the active component, the risk of leakage causing electrical shorts is reduced.

Flexibility in Coolant Type
More freedom to choose coolant (e.g. water-glycol) rather than being constrained to fully dielectric fluids.

Easier Maintenance & Leak Management
If leaks occur, they are less likely to impact the electronics directly. The cooling interface can be replaced more readily.

Modular & Scalable Design
The interface can be standardized, and the coolant loop can be shared across modules or systems.

Better Suitability for Harsh Environments
In many automotive or industrial settings, indirect cooling is preferred for robustness and durability.

Trade-offs & Challenges

 

Added Thermal Resistance
The interface layer adds a resistance penalty compared to direct contact, which can degrade maximum heat transfer.

Temperature Uniformity Issues
Hot spots may occur if the interface is not well designed or coolant flow is nonuniform.

Complex Interface Design
Designing a cold plate or manifold with optimal channel layout and contact pressure is nontrivial.

Pressure Drop & Flow Balancing
Channel layout and coolant path length must be optimized to avoid excessive pumping energy and maintain uniform flow distribution.

Material & Thermal Expansion Mismatch
The interface must handle mechanical stress arising from temperature cycling.

 

Design Strategies & Optimizations

 

To maximize performance in an indirect cooling setup, careful design and optimization are essential.

Cold Plate / Channel Geometry

Optimize channel shape (serpentine, parallel, microchannels) to balance heat transfer vs pressure drop.

Use streamlined or optimized channel designs to improve uniformity and reduce pressure drop.

Incorporate manifold design to ensure even distribution.

Contact Interface & Thermal Interface Material (TIM)

Ensure good contact (low thermal resistance) between heat source and interface.

Use high-performance TIM (e.g. graphite, phase-change pads, metal interfaces).

Coolant Selection & Flow Rates

Mixtures like 50% ethylene glycol-water (EGW) often balance freezing point, viscosity, and heat capacity. Studies show these often outperform pure water under certain constraints.

Choose operating flow rate to balance cooling margin vs pump power.

Multi-Objective Optimization

Use CFD / simulation tools to optimize between temperature uniformity, pressure drop, and energy efficiency.

Some studies use design-of-experiments (DoE) or parametric sweeps to find the best trade-offs.

Thermal Stack & Packaging Integration

Integrate the interface in the packaging layout so that mechanical, electrical, and thermal constraints are jointly satisfied.

Plan for modular repair / replacement of cold plates.

 

Applications: Where Indirect Liquid Cooling Shines

 

Battery Thermal Management in EV / Hybrid Systems

Indirect liquid cooling is the dominant approach in battery systems due to safety, modularity, and manufacturability. For cylindrical or prismatic lithium-ion cells, cold plates, jackets or tubing arrays are commonly used.

In EV applications:

The interface ensures safe isolation between coolant and battery module.

Thermal uniformity is critical for battery lifespan and safety (avoiding thermal runaway).

Researchers have shown that channel design, coolant choice, and cold plate structure heavily influence system performance.

Power Electronics & Inverters

In high-voltage inverter or power electronics systems, indirect cooling allows safer isolation between coolant circuits and high-voltage components, while still dissipating heat effectively.

Data Center / Rack-Level Cooling

Indirect liquid cooling is frequently used in rack-level or row-level cooling arrangements. For instance, servers may be cooled by air on the components, but a rear-door liquid-cooled heat exchanger captures waste heat from the hot exhaust air — a form of indirect liquid cooling.

Industrial & Telecom Module Cooling

For telecom base stations or industrial modules (e.g. inverters, RF equipment), indirect liquid cooling helps manage thermal load while preserving robustness and serviceability.

 

 Application Cases

 
LIQUID COOLING, Direct Liquid Cooling

Direct Liquid Cooling

Direct Liquid Cooling

Home / Archive by category "LIQUID COOLING"

What is Direct Liquid Cooling?

Servers have become essential in our life, particularly since institutions, companies and consumers use the Cloud daily. The number of data centers keeps increasing. Servers also become more and more powerful and therefore, generate more and more heat. While still widely used in data centers, the potential of traditional air-cooling systems is limited, more so when taking the impact on the environment into account. A few technologies based on liquid emerged, among them is direct liquid cooling (DLC), also called direct to chip liquid cooling.

How does DLC work?

The direct liquid cooling process typically works in the following order:

Cold plates mounted on processors and other power-hungry equipment absorb excess heat, preventing them from overheating.

The liquid transfers through the coolant distribution unit (CDU) into a heat exchanger.

The heat exchanger cools the liquid through air exposure or other methods, allowing it to be used again. At this point, heat is expelled from the circuit.

The liquid is sent through the cooling loop again, ready to remove heat from other components.

Benefits and Applications of Direct-to-Chip Liquid Cooling

This advanced form of liquid cooling offers several key benefits, especially in data center environments where processor chips can be prone to heat exposure:
Enhanced Cooling Efficiency: By directly applying coolant to the heat source, this method achieves more efficient heat transfer compared to air cooling. This efficiency is crucial for high-density data centers where air cooling might not suffice.
Energy Savings: Liquid cooling systems typically require less energy to operate than air cooling systems. This reduction in energy consumption translates into lower operational costs and a smaller carbon footprint for data centers.
Improved Performance: Components cooled by liquid systems can maintain higher performance levels since they are less likely to overheat. This improvement is particularly beneficial for applications requiring sustained high performance, such as scientific computing and large-scale simulations. Additionally, CPUs can run at their “boost” speeds longer than with air-cooled systems because liquid cooling keeps the CPU temperatures lower for extended periods, preventing thermal throttling and maintaining peak performance.
Space Optimization: Direct-to-chip liquid cooling allows for higher computational density, meaning fewer racks or space are needed to achieve the same compute power as compared to air-cooled systems. This space efficiency is crucial in environments where space is at a premium, allowing data centers to maximize their compute power within a smaller footprint.
Reduced Noise: Liquid cooling systems operate more quietly than air cooling systems because they rely less on large, noisy fans. This noise reduction can be a significant advantage in environments where noise levels are a concern.

Cooling Challenges for AI, HPC, and Cloud Computing

Following the booming numbers in cloud computing services, artificial Intelligence (AI) has also started to become mainstream in every part of our daily lives. Combining the high-performance computing (HPC) needed in the field of scientific research, data centers worldwide continue to grow in number and scale. As the demand for computing power rapidly expands with limited space to be utilized, data centers are forced to come up with a much higher density solution, bringing unprecedented loads to the traditional air-cooling system design. Furthermore, the vibration generated by cooling fans in a server may result in damage to server components such as HDDs, and the noise could potentially damage the hearing of workers that routinely maintain IT hardware.

It is estimated that data centers now consume approximately 1% of the world’s electricity, with the average power usage effectiveness (PUE) being in the range of 1.4 to 1.6. This number indicates that around 33% of the facility power is spent not on powering the IT hardware itself but on facility costs, including a majority part on air conditioning. DLC is a much more efficient way of transferring heat away from electrical components, and since air cooling equipment within a server, such as large fans and heat sinks, is no longer required, liquid cooling systems can fit into a more compact design, potentially supporting a much greater density of CPUs and GPUs in limited space.

Overall, the popular and standardized DLC technology has been proven effective throughout the past few years, and it is now a mature technology suitable for all scales of applications from small-sized data centers and smaller HPC cluster deployments to exascale computing facilities.

What is Direct Liquid Cooling?

Servers have become essential in our life, particularly since institutions, companies and consumers use the Cloud daily. The number of data centers keeps increasing. Servers also become more and more powerful and therefore, generate more and more heat. While still widely used in data centers, the potential of traditional air-cooling systems is limited, more so when taking the impact on the environment into account. A few technologies based on liquid emerged, among them is direct liquid cooling (DLC), also called direct to chip liquid cooling.

 

 Application Cases

 